FQ1NG M10
Multifrequency FQ1 series
Digital control of amplitude and frequency, with automatic resonance search for maximum feeding efficiency. The FQ1NG M10 is a professional microprocessor controller that adjusts both vibration amplitude and frequency digitally, then tunes the feeder to its resonance point – eliminating the long, tricky mechanical calibration of traditional controllers.
Driving electromagnetic vibratory feeders up to 10 A at 80–260 V, the M version is IP20, in a larger metallic enclosure with removable terminals for quick wiring. With frequency and amplitude display, dual PNP sensor inputs, part-flow alarm and air blow, it delivers steady, repeatable feeding for linear and bowl feeders.
Description
Professional digital microprocessor controller with frequency and amplitude display – Start or stop delay of the vibrator via PNP sensor or mechanical contact (material presence) up to a maximum of 20 seconds, adjustable – 0–10 V automatic input – Status relay – Second PNP sensor – Air blow – Part-flow alarm – Alarm lamp – Load current limitation.
Application: Digital regulation of linear and bowl feeder till 10/16 Amps – Used to optimize the operation of the vibratory feeder by searching for its resonance frequency (max performance) thereby eliminating its lengthy and difficult mechanical calibration – Enable input for multiple electromagnetic system (linear – blow feeder – hopper).
Available Versions:
| Model | Enclosure | Color | Dimensions | Code |
|---|---|---|---|---|
| FQ1NG | Metallic | Gray | 100 x 235 x 210 | PV FQ1NG Z2 M10 |
UL/CSA certification coming soon.
Options
- Customized label and SW
- Connector for vibrator
- Dual-track vibrator control (2 PNP sensors)
Additional information
| Series | Multifrequency FQ1 NG |
|---|---|
| Enclosure | Metal |
| Input Voltage [V] | 80-260 |
| Power Consumption | 2.5 W max |
| Max Output Current [A] | 10 |
| Min Load | 50 mA (RMS) |
| Vibration Frequency [Hz] | 5-140 (up to 300 on request) |
| Soft Start [s] | 0-20 |
| Min/Max Adjustment | 50V ± 30% – 200V – 30% |
| ON/OFF | Dry contact, Voltage signal |
| Blow Delay | 0-2 sec. |
| Sensor Inputs | NO/NC, NPN/PNP, Opto-isolated |
| Overflow Control | PNP1 – PNP2 (0 ÷ 20 sec.) |
| Amplitude Sensor | Sind3 |
| Automatic Input | 0/10V – 0/20 mA |
| Working Temperature | -5 °C / +55 °C |
| Relative Humidity Range | 80% up to 31 °C |
| Altitude | Up to 2000 m |
| Protection Index [IP] | IP20 (removable terminals) |
| Standard Conformity | CE, EMC, Rohs |
| Warranty | 24 months (from the date on the board) |
New products
Instruments
Vibration meter — amplitude / acceleration / frequency · 115/230 V