Similar models side by side, to help you choose the right version for your feeder. Click a model to open its product page; each table can also be downloaded as a PDF for printing.

RF4 PWM family

Amplitude-frequency controllers up to 5 A · RF4 PWM and the new RF4 PWM/N

The two lines share the same enclosures and most functions. RF4 PWM/N adds the 80–260 V wide-range input, the max current limit and the Min/Max setting; RF4 PWM keeps the fill-level control and the air-blow output. Below, only what changes between the versions.

Swipe to compare →
RF4 PWMProduct page →RF4 PWM/NNEWProduct page →
Version
RF4PWM
RF4PWM
PV RF4PW Z2 STD
RF4PWM/B
RF4PWM/B
PV RF4PW Z2 STB
RF4PWM/BD
RF4PWM/BD
PV RF4PW Z2 SBD
RF4PWM/K
RF4PWM/K
PV RF4PW Z2 STK
RF4PWM/STN
RF4PWM/STN
PV RF4PW Z2 STN
RF4PWM/BN
RF4PWM/BN
PV RF4PW Z2 SBN
RF4PWM/BDN
RF4PWM/BDN
PV RF4PW Z2 BDN
RF4PWM/KN
RF4PWM/KN
PV RF4PW Z2 SKN
Input voltage50/60 Hz115/230 V115/230 V115/230 V115/230 V80–260 V80–260 V80–260 V80–260 V
Vibration frequency30–130 Hz50/100 Hz ±12 Hz50/100 Hz ±12 Hz30–130 Hz30–130 Hz50/100 Hz ±12 Hz50/100 Hz ±12 Hz30–130 Hz
Displayamplitude / frequency——
Setpoint inputpotentiometer or PLC0–10 V · 0–20 mA0–10 V · 0–20 mA0–10 V · 0–20 mA—0–10 V · 4–20 mA0–10 V · 4–20 mA0–10 V · 4–20 mA—
Umin / Umax settingMaxMaxMax—Min / MaxMin / MaxMin / Max—
Frequency setting from PLC0–10 V———————
Max current limit5 A————
ON/OFF delay from sensorPNP/NPN0–4 s0–4 s0–4 s0–4 s0–6 s0–6 s0–6 s0–6 s
Fill level / overflow control————
Air-blow output24 V DC, 2 s delay————
DIN35 rail versionIP20 · dimensions in mm130 × 126 × 90130 × 126 × 90130 × 126 × 90—130 × 126 × 90130 × 126 × 90130 × 126 × 90—

Common to all 8 versions 13 features

  • Output voltage 0…100 V / 0…205 V
  • Output current max 5 A
  • Vibration amplitude regulation 0–100 %
  • Mains voltage compensation
  • Sinewave current output
  • Adjustable soft start
  • PNP/NPN sensor supply 24 V DC
  • External enable 24 V DC or volt-free contact
  • Status relay 250 V, 1 A, yellow LED
  • Resident software by M.P.
  • Metal box IP65, 130 × 130 × 95 mm
  • CE and EMC conformity
  • Custom label on request

FQ NG series

Digital amplitude-frequency controllers with SIND3 amplitude sensor · FQ1NG · FQ2NG · FQ3NG

Same control platform across the three series. They differ in output current, display, sensors and enclosure: FQ1NG and FQ2NG are the complete versions, up to 16 A in a metal enclosure and up to 8 A in a compact aluminium one; FQ3NG is the essential version, up to 8 A, with a single PNP sensor and fewer functions.

Swipe to compare →
Series
FQ1NG
10 · 16 · M10 · M16
FQ2NG
FQ3NG
Output current10 / 16 A6 / 8 A6 / 8 A
DisplayGraphicLCD (segments)Graphic (GFC) or LCD
Setpoint input from PLC0–10 V · 0–20 mAGFC only
PNP sensor inputs2nd sensor with 2 delays and 24 V output221
Twin-track min/max logic—
AC 230 V motor output—
Pulse ON/OFF—
Multi-language menu—
Enclosuredimensions in mmMetal, 100 × 225 × 210
M versions: 100 × 235 × 210
Aluminium, 100 × 250 × 105
M versions: 100 × 240 × 105
Aluminium, 100 × 185 × 105
M versions: 100 × 225 × 105
Connectionsprotection classIP55
M versions: removable terminals, IP20
M12 connectors, IP55
M versions: removable terminals, IP20
M12 connectors, IP55
M versions: removable terminals, IP20
UL/CSA certificationComing soonComing soon—

Common to the three series 22 features

  • Input voltage 80–260 V, 50/60 Hz
  • Output voltage 0…100 V / 0…205 V
  • Vibration frequency 5–140 Hz in 0.1 Hz steps (up to 300 Hz on request)
  • Vibration amplitude regulation
  • Mains voltage compensation
  • Resonant frequency search (AFC)
  • Closed-loop control with SIND3 amplitude sensor (M12)
  • Max current limit
  • Real-time working current reading
  • Umin / Umax setting from keyboard
  • Coarse / fine control
  • Soft start 0–20 s
  • Fill level / overflow control, PNP 24 V DC, delay up to 20 s
  • Sensor supply 24 V DC (100 mA)
  • External enable 24 V DC or volt-free contact
  • Status signal: changeover relay 250 V, 1 A
  • Air blow, delay 0–2 s
  • 5 saved settings
  • Custom password
  • User-friendly resident software by M.P.
  • CE, EMC and RoHS conformity
  • Custom label on request