Similar models side by side, to help you choose the right version for your feeder. Click a model to open its product page; each table can also be downloaded as a PDF for printing.
RF4 PWM family
Amplitude-frequency controllers up to 5 A · RF4 PWM and the new RF4 PWM/N
The two lines share the same enclosures and most functions. RF4 PWM/N adds the 80–260 V wide-range input, the max current limit and the Min/Max setting; RF4 PWM keeps the fill-level control and the air-blow output. Below, only what changes between the versions.
| RF4 PWMProduct page → | RF4 PWM/NNEWProduct page → | |||||||
|---|---|---|---|---|---|---|---|---|
| Version | ![]() RF4PWM PV RF4PW Z2 STD | ![]() RF4PWM/B PV RF4PW Z2 STB | ![]() RF4PWM/BD PV RF4PW Z2 SBD | ![]() RF4PWM/K PV RF4PW Z2 STK | ![]() RF4PWM/STN PV RF4PW Z2 STN | ![]() RF4PWM/BN PV RF4PW Z2 SBN | ![]() RF4PWM/BDN PV RF4PW Z2 BDN | ![]() RF4PWM/KN PV RF4PW Z2 SKN |
| Input voltage50/60 Hz | 115/230 V | 115/230 V | 115/230 V | 115/230 V | 80–260 V | 80–260 V | 80–260 V | 80–260 V |
| Vibration frequency | 30–130 Hz | 50/100 Hz ±12 Hz | 50/100 Hz ±12 Hz | 30–130 Hz | 30–130 Hz | 50/100 Hz ±12 Hz | 50/100 Hz ±12 Hz | 30–130 Hz |
| Displayamplitude / frequency | — | — | ||||||
| Setpoint inputpotentiometer or PLC | 0–10 V · 0–20 mA | 0–10 V · 0–20 mA | 0–10 V · 0–20 mA | — | 0–10 V · 4–20 mA | 0–10 V · 4–20 mA | 0–10 V · 4–20 mA | — |
| Umin / Umax setting | Max | Max | Max | — | Min / Max | Min / Max | Min / Max | — |
| Frequency setting from PLC0–10 V | — | — | — | — | — | — | — | |
| Max current limit5 A | — | — | — | — | ||||
| ON/OFF delay from sensorPNP/NPN | 0–4 s | 0–4 s | 0–4 s | 0–4 s | 0–6 s | 0–6 s | 0–6 s | 0–6 s |
| Fill level / overflow control | — | — | — | — | ||||
| Air-blow output24 V DC, 2 s delay | — | — | — | — | ||||
| DIN35 rail versionIP20 · dimensions in mm | 130 × 126 × 90 | 130 × 126 × 90 | 130 × 126 × 90 | — | 130 × 126 × 90 | 130 × 126 × 90 | 130 × 126 × 90 | — |
Common to all 8 versions 13 features
- Output voltage 0…100 V / 0…205 V
- Output current max 5 A
- Vibration amplitude regulation 0–100 %
- Mains voltage compensation
- Sinewave current output
- Adjustable soft start
- PNP/NPN sensor supply 24 V DC
- External enable 24 V DC or volt-free contact
- Status relay 250 V, 1 A, yellow LED
- Resident software by M.P.
- Metal box IP65, 130 × 130 × 95 mm
- CE and EMC conformity
- Custom label on request
FQ NG series
Digital amplitude-frequency controllers with SIND3 amplitude sensor · FQ1NG · FQ2NG · FQ3NG
Same control platform across the three series. They differ in output current, display, sensors and enclosure: FQ1NG and FQ2NG are the complete versions, up to 16 A in a metal enclosure and up to 8 A in a compact aluminium one; FQ3NG is the essential version, up to 8 A, with a single PNP sensor and fewer functions.
| Series | ![]() | ![]() | ![]() |
|---|---|---|---|
| Output current | 10 / 16 A | 6 / 8 A | 6 / 8 A |
| Display | Graphic | LCD (segments) | Graphic (GFC) or LCD |
| Setpoint input from PLC0–10 V · 0–20 mA | GFC only | ||
| PNP sensor inputs2nd sensor with 2 delays and 24 V output | 2 | 2 | 1 |
| Twin-track min/max logic | — | ||
| AC 230 V motor output | — | ||
| Pulse ON/OFF | — | ||
| Multi-language menu | — | ||
| Enclosuredimensions in mm | Metal, 100 × 225 × 210 M versions: 100 × 235 × 210 | Aluminium, 100 × 250 × 105 M versions: 100 × 240 × 105 | Aluminium, 100 × 185 × 105 M versions: 100 × 225 × 105 |
| Connectionsprotection class | IP55 M versions: removable terminals, IP20 | M12 connectors, IP55 M versions: removable terminals, IP20 | M12 connectors, IP55 M versions: removable terminals, IP20 |
| UL/CSA certification | Coming soon | Coming soon | — |
Common to the three series 22 features
- Input voltage 80–260 V, 50/60 Hz
- Output voltage 0…100 V / 0…205 V
- Vibration frequency 5–140 Hz in 0.1 Hz steps (up to 300 Hz on request)
- Vibration amplitude regulation
- Mains voltage compensation
- Resonant frequency search (AFC)
- Closed-loop control with SIND3 amplitude sensor (M12)
- Max current limit
- Real-time working current reading
- Umin / Umax setting from keyboard
- Coarse / fine control
- Soft start 0–20 s
- Fill level / overflow control, PNP 24 V DC, delay up to 20 s
- Sensor supply 24 V DC (100 mA)
- External enable 24 V DC or volt-free contact
- Status signal: changeover relay 250 V, 1 A
- Air blow, delay 0–2 s
- 5 saved settings
- Custom password
- User-friendly resident software by M.P.
- CE, EMC and RoHS conformity
- Custom label on request